Abdominal Aortic Disease
Abdominal Aortic Aneurysm
In this disease, the abdominal aorta is enlarged to 1.5 times of the normal diameter. It is the most common arterial dilatation disease. It can be life-threatening once it’s ruptured and bleeding. Abdominal aortic aneurysm cannot heal itself if left untreated. Once ruptured, its mortality rate is as high as 70% to 90%. But its mortality rate after elective surgery can be dropped to less than 5%. Therefore, early diagnosis and early treatment should be performed.
Minos™ Abdominal Aortic Stent-Graft and Delivery System
Minos™ is indicated for the endovascular treatment of infrarenal abdominal aortic aneurysm. It is a new generation of abdominal aorta stent graft system independently developed by Endovastec™. Its delivery sheath outer diameter is only 14F, which significantly reduces the requirements for vascular access during surgery. The stent structure adopts a tri-modular design, which can be flexibly assembled in the body to meet different anatomical needs and cover the common iliac artery lesion area to the greatest extent. In addition, designs such as “Laser cut bare stent with barbs”, “seamless multifilament graft”, “multi-mini springs at the proximal end of the main stent”, and “helical limb stent” can meet the treatment needs of more abdominal aortic aneurysms with complex anatomy, reduce the incidence of common complications such as stent displacement, endoleak, and branch stent occlusion, reduce the risk of long-term secondary intervention while ensuring the stent’s long-term stability.
Product Features:
Stent graft:
Delivery system:
This product may not be available in all countries or regions. For more information on product availability, please contact your local representative.
Aegis™ Bifurcated Aortic Stent Graft System
Aegis™ is indicated for infrarenal abdominal aortic aneurysm with the proximal aneurysm neck length over 15 mm. It is the only stent graft in China that adopts a one-piece structure. The stent straddles the bifurcation of the aorta to avoid the risk of distal displacement; the one-piece design is easy to operate and requires no contralateral incision and limb connection. It also eliminates the risk of type III endoleak. It is the first choice for local aneurysm stenosis and abdominal aortic dissection. In addition, it can provide a tailored design for the patient.
Product Features:
This product may not be available in all countries or regions. For more information on product availability, please contact your local representative.
Hercules™ Bifurcated Stent-Graft System
Hercules™ Bifurcated Stent-Graft System is indicated for infrarenal abdominal aortic aneurysm with proximal aneurysm neck length over 15 mm. The stent graft system adopts a two-pieces design, is assembled in the patient, and the operation and release are simple and easy. The heightened design of the branch segment makes the stent more adaptable to the twisted iliac artery.
Product Features:
This product may not be available in all countries or regions. For more information on product availability, please contact your local representative.
Hercules™ Balloon Inflation Catheter
Hercules™ Balloon is designed to assist expansion of stents after EVAR procedure. It is intended to eliminate type I/III endoleak and reinforce the attachment of the stent graft to the aortic wall by means of fully expanding the stent graft, so as to achieve the better short-term and long-term treatment effects.
Product Features:
It is intended to eliminate type I/III endoleak and reinforce the attachment of the stent graft to the aortic wall by means of fully expanding the stent graft.
This product may not be available in all countries or regions. For more information on product availability, please contact your local representative.